RM Analyzer Help

Cable shortening by force (FX0)

Definition of the stress free length of a cable by specification of the equivalent stressing force.

Note: For detailed load explanation see also RM Bridge Load Types Library .
SettingDescription
From, To, Step Element series to be loaded
Assembly Alternative to load assignment via element series: Name of the assembly to be loaded. The specified load is applied to every element of the specified assembly.
Fx (kN) Normal force being equivalent to the desired length change dL = L* Fx/(EA) 
[OK+Series] To continue with further input of the same load type